FLOOR SYSTEMS
- 24', 25' wide units - 16" OC 2 x 8 floor joists with solid wood bridging, double 2 x 8 S.P.F. perimeter joists glued and nailed under load bearing walls. Double 2 x 8 S.Y.P. perimeter joists in each box under marriage wall.
- 26', 27'6' wide units - double 2 x 10 S.P.F. perimeter joists glued and nailed under load bearing walls, 16" OC 2 x 10 floor joists with solid wood bridging.
- 31'6 wide units - double 2 x 10 S.P.F. perimeter joists glued and nailed under load bearing walls, 12" OC 2 x 10 S.P.F. floor joists with solid wood bridging.
- 3/4" Tongue and groove OSB sub-floor glued and nailed.
EXTERIOR WALLS
- 2 x 6 S.P.F. studs, 16" OC exterior wall construction with a single bottom plate, double top plate for all load bearing walls including R-19 fiberglass insulation.
- Double 2 x 3 S.P.F. marriage wall 16" OC with 1/8" Thermo-Ply sheathing on one side.
- 7/16" OSB exterior wall sheathing
INTERIOR WALLS
- 2 x 4 S.P.F. studs, 24" OC interior wall partitions with a single bottom plate and a single top plate.
- ½" Drywall interior finished with two (2) PRIMER COATS of paint.
- 8' Ceiling height.
ROOF AND CEILING
- 7/12 STD truss roof 24" OC
- ½" OSB roof sheathing.
- 30 Year architectural shingles installed over roof paper underlayment and aluminum drip edge.
- Ice and water barrier (per code).
- R-30 fiberglass ceiling insulation.
- Double 2 x 12 S.P.F. perimeter joists and 2 x 6 S.P.F. ceiling joists, 16" OC (1st story on two-story models).
- 5/8" Drywall ceiling.
- Shingle over rolled ridge vent.
- 10" Eave overhangs with aluminum fascia and vinyl vented soffit (24' and 25' wide have fixed eaves only, 26', 27'6, and 31'6 wide have folding eaves).
- 1 1/2" Gable overhangs with aluminum fascia.
INTERIOR
- 25 Ounce FHA approved carpet with 7/16" x 6 pound FHA approved re-bond pad.
- Vinyl floor covering installed in kitchen, baths and utility rooms.
- Six panel white hollow-core colonial doors, pre-hung on wood jambs with matching colonial moldings pre-finished white.
- 2 ¼" colonial casing and 3 ¼" colonial pine base pre-finished white.
- Privacy lock sets on doors to baths and master bedroom in satin nickel or polished brass, remainder are passage.
- Door stops.
- Vented closet and pantry shelves with clothes bar.
EXTERIOR
- Fiberglass insulated six-panel front door and fiberglass insulated rear door with half glass (with keyed alike satin nickel or polished brass lock sets), or vinyl patio door (floor plan dictates).
- MW White vinyl tilt, double hung windows with stools and screens (Low E specs).
- Vinyl siding, available in double 4" or Dutch Lap (double 5") over 7/16" OB exterior wall sheathing.
- Aluminum fascia and vented vinyl soffit.
- Exterior porch lights in either brushed nickel or polished brass.
- Front and rear door bells (2 locations).
PLUMBING
- Washerless faucets.
- Pex Fresh water supply lines stubbed through floor..
- Shut-off valves on each fixture.
- Tub/shower valves with integral stops.
- PVC schedule 40 drain, waste and vent system.
ELECTRICAL
- Wired per National Electric Code.
- 200 AMP, 40 position main service panel box with main breaker, individual circuit breakers and cover.
- Two exterior weatherproof receptacles with G.F.I. protection (front and rear).
- G.F.I. protection on receptacles at kitchen sink and at lavatories.
- White toggle switches and receptacles throughout.
- AC/DC smoke detectors - one per floor and one each bedroom.
- Ceiling lights in kitchen, dinning room, hall, foyer, stairwells and above kitchen sink in brushed nickel or polished brass.
- Fan/light combination and medicine cabinet light in all baths.
- 3 Way switch, wire and J-box for on-site basement light.
- Switch, wire and J-box for attic light (Attic Truss Only).
- Std location for thermostat wires will be on the living room marriage wall for 1st floor, and on hall wall for second floor unless called out otherwise by builder.
- 1 CO2 detector per home.
- NEC Arc protection in bedroom locations.
HEATING
- Electric baseboard heat with individual wall mounted thermostats in each room - 90 degree max (except 75 degrees in NY per code) or hot water baseboard heating elements (optional charge for hot water baseboard in two story units).
- Heat plant for hot water baseboard supplied by builder.
KITCHEN
- Merillat Essential Cabinetry - Oak door in Millbridge recessed panel or Pemberton raised panel design.
- Laminate self-edge countertop with backsplash.
- 30" Vented range hood with light in white or biscuit.
- Double bowl 8" deep stainless steel sink with single-lever faucet assembly and sprayer.
- Crown molding over wall cabinets.
BATH
- 60" one piece fiberglass tub/shower combination.
- Fiberglass shower stall (floor plan dictates).
- Anti-scald valves in tubs and showers.
- Elongated 1.6 gallon low flow water closet.
- Vanity cabinets to match kitchen cabinets.
- Cultured marble swirl top with integral oval bowl and single lever faucet.
- Medicine cabinet with light.
- Combination fan/light ventilation unit.
- Towel bar and toilet paper holder.
ADDITIONAL BASELINE SPECIFICATIONS
GARAGE SPECIFICATIONS
Exterior
- Header height is against the bottom of the top plate.
- Panelized garage walls are 10 ½" taller than exterior walls.
- Roof sheathing and singles are only included with Easy Living garage packages. (Must Order Separately).
- Trusses panelized and on-site garages will require a parts carrier.
Electrical
- 1 overhead light.
- 1 receptacle on each interior wall (dedicated circuit).
- 1 receptacle above each garage door located 10' from wall.
- Breaker Box, if located in garage, is mounted 16" below std interior height.
- Receptacles are mounted 10" above std interior height.
- Switches are mounted 16" below std interior height.
|
|
|
 |
|